InterServer began providing web hosting services in 1999. Our datacenter's include a 100% power uptime guarantee and a 99.9% network uptime guarantee.

Secaucus Datacenter Information - TEB1

110A Meadowlands Parkway, Secaucus New Jersey

Facility Features

  • 8,000 Sq Ft Facility
  • 6,500 Sq Ft. Datacenter
  • (4) HVAC Units Totaling 80 Tons
  • Overhead A/C Ducts for Air Distribution
  • Pre-action Dry Pipe Sprinkler System
  • ADT Security Badge Entrance
  • 2,000 AMPS of 480v Input Power
  • (2) 500KVA Powerware UPS units

Secaucus Datacenter Information - TEB2

110B Meadowlands Parkway, Secaucus New Jersey

Facility Features

  • 8,000 Sq Ft Facility
  • 6,500 Sq Ft. Datacenter
  • (4) HVAC Units Totaling 80 Tons
  • Raised Flooring
  • Biometric Entry Into Building
  • 2,000 AMPS of 480v Input Power
  • (2) 150KVA UPS units

Los Angeles Datacenter Information - LAX1

Los Angeles is home to many of our Internet content and entertainment customers, such as motion pictures, television, video games, and recorded music firms. With network traffic growing exponentially due to use of video on the Web, Equinixs IBX centers in the Los Angeles area have been key to the network strategies of Internet content and entertainment companies looking to reach their end-users quickly.

LA3 Technical Specifications

  • Electrical Capacity – 2.4 kVA per cabinet
  • UPS Configuration – N+1 Block
  • Redundant System
  • # of Utility Feeders – 2
  • # of Power Transformers – 10
  • Utility Voltage – 16,340 volts, 3-phase
  • Standby Power – Eleven 2,000 kW diesel engine-generator power
  • Standby Power Config. – N+1
  • Cooling Capacity – 2.5 kW per cabinet (8,533 BTUH)
  • Cooling Plant – Air and water cooled chillers & CRAC units
  • Physical "Man trap" entry
  • Human 24x7 security guards
  • Electronic CCTV and Recorders, Motion Detection, Hand Geometry Readers, Fiber Vault
  • System Overhead proprietary cable tray system with multi-tier ladder rack
  • Cross Connects Single-Mode fiber, Multi-Mode fiber (62.5 and 50 micron), CAT5, CAT6, CAT5 (T1), and CAT3 (POTS)
  • Equinix Metro Connect Extends choice and reach for carrier and network availability across metro areas
  • Equinix Internet Exchange Central switch for public and private peering

Datcenter Photographs

  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4
  • example4